| T C | |||||||||
| Model | Measurement MGM-D-6.5-HC MGM-D-10-HC MGM-D-12-HC MGM-D-14HC MGM-D-16-HC MGM-D-20-HC MGM-D-23-HC MGM-D-30-HC | ||||||||
| Power supply | 380~415V/50Hz/3ph(60Hz model can be customized produced) | ||||||||
| Nominal heating condition (A-12W41) |
heating capacity(KW) |
6.5 | 10.0 | 12.2 | 14.4 | 16.0 | 20.6 | 23.0 | 30.1 |
| COP(W/W) | 2.30 | 2.38 | 2.53 | 2.53 | 2.47 | 2.55 | 2.55 | 2.35 | |
| Input power(KW) | 2.83 | 4.20 | 4.8 | 5.7 | 6.5 | 8.1 | 9.0 | 12.8 | |
| Rated heating condition (A7W45) |
heating capacity(KW) |
8.5 | 16.0 | 18.2 | 20.5 | 22.5 | 27.0 | 30.0 | 42.2 |
| COP(W/W) | 3.00 | 3.15 | 3.13 | 3.14 | 3.13 | 3.20 | 3.40 | 3.13 | |
| Input power(KW) | 2.83 | 5.08 | 5.8 | 6.5 | 7.2 | 8.4 | 8.8 | 13.5 | |
| Low ambient tem.condition (A-20W41) |
heating capacity(KW) |
5.30 | 8.49 | 10.0 | 11.0 | 13.5 | 17.5 | 18.5 | 25.5 |
| COP(W/W) | 2.12 | 2.15 | 2.12 | 2.13 | 2.13 | 2.20 | 2.11 | 2.10 | |
| Input power(KW) | 2.50 | 3.95 | 4.7 | 5.2 | 6.3 | 8.0 | 8.8 | 12.1 | |
| Nominal cooling condition (A35W7) |
Cooling capacity(KW) |
6.5 | 10.0 | 11.0 | 14.4 | 15.5 | 20.4 | 21.4 | 30.0 |
| EER(W/W) | 2.25 | 2.30 | 2.52 | 2.52 | 2.52 | 2.53 | 2.51 | 2.52 | |
| Input power(KW) | 2.89 | 4.35 | 4.4 | 5.7 | 6.2 | 8.1 | 8.5 | 11.9 | |
| Domestic hot water heating condition(A20/ W15-55℃) |
Heating capacity(KW) |
12.0 | 21.4 | 24.7 | 27.9 | 30.3 | 35.8 | 37.1 | 56.6 |
| COP(W/W) | 4.22 | 4.21 | 4.25 | 4.28 | 4.21 | 4.24 | 4.20 | 4.20 | |
| Input power(KW) | 2.83 | 5.08 | 5.8 | 6.5 | 7.2 | 8.4 | 8.8 | 13.5 | |
| Voltage | / | 220V~240V/1ph | 220V1ph or 380V-3ph | 380V-3ph | |||||
| Max.input power | KW | 3.8 | 5.7 | 5.7 | 7.4 | 8.0 | 10.5 | 11.1 | 15.5 |
| Max.currency | A | 17.07 | 25.69 | 220V:25.9 380V:9.26 |
220V:33.6 380V:12 |
13.2 | 17.2 | 18.2 | 25.5 |
| Refrigerant | / | R410a/R32/R290 | |||||||
| Condenser(2 options) |
/ | *Option1:High efficiency tube in shell tank type heat ex changer *Option 2:High efficiencyplate type heatex changer condenser | |||||||
| Evaporator | / | L-shape high efficiency aluminum fins+copper refrigerant flow tubes | |||||||
| Fan quantity | PCS | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 |
| Noise | dB | 55 | 55 | 55 | 58 | 58 | 60 | 60 | 60 |
| Connection | DN25 | DN25 | DN25 | DN25 | DN25 | DN40 | DN40 | DN40 | |
| Water pump | / | Internal variable frequency water pump | External(not included) | ||||||
| waterflow rate | m³/h | 1.8 | 3.5 | 3.6 | 4.2 | 5 | 6 | 7.5 | 9 |
| Pressure drop | Kpa | 40 | 40 | 40 | 50 | 50 | 55 | 55 | 55 |
| Workingambient temperature |
℃ | -30~43 | |||||||
| House area (recommend) |
M² | 60 | 100 | 120 | 140 | 150 | 200 | 220 | 290 |
| Ext.dimension (L/W/H) |
MM | 1030 | 1055 | 1055 | 1055 | 1207 | 1207 | 1207 | 1207 |
| MM | 380 | 405 | 405 | 405 | 530 | 530 | 530 | 530 | |
| MM | 800 | 985 | 1363 | 1363 | 1455 | 1455 | 1455 | 1455 | |